DATA CENTER IN A ROW (DCR)

 

 

Data Center In A Row, a totally integrated, closed architecture, data center. The DCR provides power, security, fire detection & suppression, 17.5 kW of cooling, management, monitoring and back up cooling for network closets and data centers.

The DCR can be provided with Pin and Sleeve connectors for easy relocation and fast depreciation.

The system can be expanded for larger capacities with the addition of cooling and fire detection/ suppression modules.

 

FEATURES:

3 OR 4 - Nema 1 - 42u RACKS IN SELF CONTAINED INTEGRATED MODULE

17.5 Kw DX OR CHILLED WATER COOLING SYSTEM

TOTAL FIRE DETECTION AND SUPPRESSION

POWER AND COOLING SYSTEM MONITORING - LOCAL AND REMOTE

BACK UP COOLING SYSTEM

CLOSED ARCHITECTURE FOR QUIET OPERATION (70 dbA @ 3')

PROVIDED WITH QUICK CONNECTS FOR EASY RELOCATION AND 5 YEAR DEPRECIATION

POWER DISTRIBUTION FOR UTILITY AND UPS POWER

LARGE SELECTION OF RACK PDUs

VARIOUS UPS SELECTIONS - N, N+1, 2N OR INDIVIDUAL RACK MOUNTED

EXPANDABLE TO 6 - 8 RACKS OR MORE WITH MULTIPLE COOLING/POWER MODULES

RELOCATABLE TO BACK UP SITE OR REMOTE SITE

SMALL FOOTPRINT - 3 RACK SYSTEM - 104” L X 42.5” D X 96” H

BALANCING DAMPERS IN EACH RACK TO INSURE PROPER COOLING AIR IS PROVIDED AS DICTATED BY THE LOAD OF EACK RACK

 

DATA CENTER IN A ROW WITH N+1 COOLING

 

If redundant cooling is required, a second cooling only module is provided complete with an auto changeover controller. The cooling systems are alternated on a weekly basis to insure integrity of the cooling systems.

The cooling systems can be air-cooled water-cooled, glycol-cooled or chilled water cooled to meet specific site requirements. Each cooling module provides 17.5 kW of cooling. Utilizing adjustable air dampers in each rack, the correct amount of cooling is insured to meet the load conditions of that rack.

In addition to mechanical cooling, the 3 rack system includes duct-able backup cooling fans. These fans are powered by the internal UPS systems and will operate automatically upon temperature rise in the cabinets. Room air is drawn into the base of each rack through atmospheric dampers.

 

EXPANDED DATA CENTER IN A ROW WITH N+1 COOLING

 

 

For every three to four computer racks added, an additional cooling/power distribution module complete with a slave fire detection/suppression system is provided. In addition one cooling only module can be included to provide N+ cooling as shown above.

 